Model 2363 Gamma/Neutron Survey Meter with Model 42-41 PRESCILA Probe

INDICATED USE: Gamma and Neutron Survey
SUGGESTED DETECTORS:
EXTERNAl: Model 42-41 PRESCILA detector
INTERNAL: Energy-compensated GM detector
SENSITIVITY:
Gamma: 1000 cpm per mrem/hr (internal detector)
;Neutron: 350 cpm per mrem/hr (with Model 42-41)
ADJUSTABLE ALARMS (Indicated by front panel - red LEDS):
Gamma alarm
Neutron alarm
Integrated dose alarm

LOGGING PUSHBUTTON: Located in the handle; used to store a reading
DATA LOGGER: Capable of logging up to1000 individual data points with the following identifiers for each point (All data is stored in non- volatile memory, allowing batteries to be removed without loss of data):
gamma and neutron sample counts
;sample number
date/time stamp
current integrated dose
10 character location identifier

RS-232 PORT: Located on the can, this allows the instrument to be connected to a PC for data download, and adjustment of setup parameters.
CONNECTOR: Series “C” (others available on request )
AUDIO: Built in unimorph speaker with volume control (greater than 60 dB at 2 feet, full volume )
AUDIO DIVIDE: Selectable dual or individual click-per-event for gamma and neutron counts
METER: 2.5"(6.4cm) arc, 1 mA analog type
METER DIAL: 0 - 10 mrem/hr, BAT OK, (overload) MULTIPLIERS: X0.1, X1, X10, X100
LINEARITY: Reading within 10% of true value DIGITAL DISPLAY: 6 digit LCD with 0.25" digits
SELECTOR SWITCH: Toggle switch to select gamma+neutron, gamma only, or neutron only
RESET/READ HV: A two position momentary action switch to allow for the meter to be reset or a reading of the current integrated dose on the digital display
RESPONSE: Will vary according to the number of counts present. Typically 2 - 11 seconds from
10% - 90% of final reading
POWER: 2 each “D” cell batteries (housed in sealed compartment that is accessible from front of instrument)
BATTERY LIFE: Greater than 150 hours (battery condition can be checked on meter )
CONSTRUCTION: Cast and drawn aluminum with beige polyurethane enamel paint
TEMPERATURE RANGE:
GAMMA: -4° F(-20° C) to 122° F(50° C)
NEUTRON: 14° F(-10° C) to 122° F(50° C)
SIZE: 6.5"(16.5cm)H X 3.5"(8.9cm)W X 8.5"(21.6cm)L
WEIGHT: 3.5 lbs (1.6kg) including batteries

Prescila

Model 42-41 PRESCILA Probe

INDICATED USE: Neutron Survey
DETECTOR: PRESCILA Proton Recoil Scintillator
SENSITIVITY: Approximately 350 cpm per mrem/h
NEUTRON ENERGY RESPONSE: Thermal to 100MeV
ANGULAR DEPENDENCE: Within 15% over wide range of energies
GAMMA REJECTION: Approximately 500 cpm at 100mR/h (137Cs)
SUGGESTED INSTRUMENTS: Ludlum Models 12,  2363, 2241 series, and 2350-1
OPERATING VOLTAGE: Typically 500 - 700 volts
CONNECTOR: Series “C” (others available on request)
CONSTRUCTION: Aluminum housing w/black powdercoat finish
SIZE:10.125"(25.7cm)H X 4.25"(10.80 cm)W X 4.25"(10.80 cm)L
WEIGHT: 4.46 lbs.

 

 

Manual

Nuclear Instrumentation

Dosimetry Shielding Sources Specials

Hepa Vacuums

Chemical Detection

Marinelli Beakers

Fume Hoods

Accessories

Emergency Response

Nuclear Medicine

Radiation Therapy Search Home

Direct Scientific    tel (310) 589 0601   fax (310) 919-2981,   Email

contact us: en español, auf Deutsch
Open 8:00 AM - 5:00 PM Pacific Standard Time