Model 14CRK Response Kit

 

  • 5 Range Survey Meter
  • Internal High Range G-M Detector
  • Alpha Beta Gamma Pancake G-M
  • 1" X 1" NaI(Tl) Gamma Scintillator
  • Check Source
  • Total Range from 0 - 2000 mR/hr

PART NUMBER:48-2653

 

DETECTORS: Model 44-9 Pancake G-M, Model 44-2 Gamma Scintillator (others available)
METER DIAL:Typically 0 - 2 mR/hr and 6.8k cpm, BAT TEST (others available )
MULTIPLIERS: X0.1, X1, X10, X100, X1000
LINEARITY: Reading within plus or minus 10% of true value with detector connected
CONNECTOR: Series "C" (others available )
INTERNAL DETECTOR: Energy compensated G-M (used with X1000 scale only )
ENERGY RESPONSE: Within plus or minus 15% of true value between 60 keV - 3 MeV (internal detector only )
THRESHOLD: 30 mV plus or minus 10 mV
AUDIO: Built in unimorph speaker with ON/OFF switch (greater than 60 dB at 2 feet )
CALIBRATION CONTROLS: Accessible from front of instrument (protective cover provided )
HIGH VOLTAGE:900 volts
THRESHOLD: 30 mV plus or minus 10 mV
RESPONSE: Toggle switch for FAST (4 seconds) or SLOW (22 seconds) from 10% to 90% of final reading
RESET: Push-button to zero meter
POWER: 2 each "D" cell batteries (housed in sealed compartment that is externally accessible )
BATTERY LIFE: Typically 600 hours with alkaline batteries (battery condition can be checked on meter )
METER: 2.5" (6.4 cm) arc, 1 mA analog type
CONSTRUCTION: Cast and drawn aluminum with beige polyurethane enamel paint
TEMPERATURE RANGE: -4° F(-20° C) to 122° F(50° C)
May be certified for operation from -40° F(-40° C) to 150° F(65° C)
SIZE: 6.5" (16.5 cm)H X 3.5" (8.9 cm)W X 8.5" (21.6 cm)L
WEIGHT: 3.5 lbs (1.6 kg) including batteries

Model 44-9 Pancake G-M detector

INDICATED USE: Alpha beta gamma survey; Frisking
DETECTOR: Pancake type halogen quenched G-M
WINDOW: 1.7 plus or minus 0.3 mg/cm² mica
WINDOW AREA:
Active - 15 cm²
Open - 12 cm²
EFFICIENCY(4pi geometry): Typically 5%-C-14; 22%-Sr-90/Y-90; 19%-Tc-99; 32%-P-32; 15%-Pu-239
SENSITIVITY: Typically 3300 cpm/mR/hr (Cs-137 gamma )
ENERGY RESPONSE: Energy dependent
DEAD TIME: Typically 80 microseconds
COMPATIBLE INSTRUMENTS: General purpose survey meters, ratemeters, and scalers
OPERATING VOLTAGE: 900 volts
CONNECTOR: Series "C" (others available )
CONSTRUCTION: Aluminum housing with beige polyurethane enamel paint
TEMPERATURE RANGE: -4° F(-20° C) to 122° F(50° C)
May be certified for operation from -40° F(-40° C) to 150° F(65° C)
SIZE: 1.8" (4.6 cm)H X 2.7" (6.9 cm)W X 10.7" (27.2 cm)L
WEIGHT: 1 lb (0.5kg)

Model 44-2 Gamma Scintillator

INDICATED USE: High energy gamma detection
SCINTILLATOR: 1" (2.5 cm) diameter X 1" (2.5 cm) thick sodium iodide (NaI)Tl scintillator
SENSITIVITY: Typically 175 cpm/microR/hr (Cs-137)
COMPATIBLE INSTRUMENTS: General purpose survey meters, ratemeters, and scalers
TUBE: 1.5:(3.8cm) diameter magnetically shielded photomultiplier
OPERATING VOLTAGE: Typically 500 - 1200 volts
DYNODE STRING RESISTANCE: 100 megohm
CONNECTOR: Series "C" (others available )
CONSTRUCTION: Aluminum housing with beige polyurethane enamel paint
TEMPERATURE RANGE: -4° F(-20° C) to 122° F(50° C)
May be certified for operation from -40° F(-40° C) to 150° F(65° C)
SIZE: 2" (5.1 cm) diameter X 7.3" (18.5 cm)L
WEIGHT: 1 lb (0.5kg)

METER DIAL

202-608
0 - 6.6kcpm; 0-2 mR/hr

 

Nuclear Instrumentation

Dosimetry Shielding Sources Specials

Hepa Vacuums

Chemical Detection

Marinelli Beakers

Fume Hoods

Accessories

Emergency Response

Nuclear Medicine

Radiation Therapy Search Home

Direct Scientific    tel (310) 589 0601   fax (310) 919-2981,   Email

contact us: en español, auf Deutsch
Open 8:00 AM - 5:00 PM Pacific Standard Time