INDICATED USE: Hazard assessment, emergency re- sponse
DETECTORS: Internal energy-compensated GM detectors
ALERT/ALARM: Indicated by annunciator on display and audible tone
DISPLAY: 4 digit LCD display with 0.5"(1.3cm) high digits, separate annunciators for display units, alert, alarm, low battery, detector overload
BACKLIGHT: Push-button to activate
EFFECTIVE RANGE: Low 0.1mR/hr - 999.9 mR/hr
High 0.1 Rhr - 999.9 R/hr
HIGH VOLTAGE: Two independent controls; each adjustable from 200 - 2500 volts
DISCRIMINATOR: Two independent controls; each adjustable from 2 - 100 mV
OVERLOAD: Indicated by OVERLOAD on display
BATTERY LIFE: Typically 200 hours with alkaline batteries
(24 hours when low battery is first indicated on display)
SIZE:6.5"(16.5cm)H X 3.5"(8.9cm)W X 8.5"(21.6cm)L
WEIGHT: 3.5 lbs (1.6kg) including batteries
RESPONSE TIME: < 4 seconds at 10 mR/hr
ALARM: Flashing daylight-visible LED indication

The following parameters are adjusted by a removable switchboard. Once initial setup and
calibration have been completed the switchboard can be removed without affecting normal
operation of the instrument (Model 2242 may be ordered without switchboard )
BACKLIGHT “ON” TIME: 5, 30, 60, 90, 180, or 240 seconds for the backlight to stay “ON” when activated.
RS-232 DATA DUMP MODE: Enables or disables dump mode to RS-232 port. When enabled data will be dumped every 2 seconds
RS-232 DETECTOR SETUP MODE: Allows for detector parameters to be input by RS-232 port
BAUD RATE: 150, 300, 600, 1200, 2400, 4800, 9600, or 19200 bps.
DEAD TIME: Adjustable from 0 - 9999 µseconds
CALIBRATION CONSTANT: Adjustable from 0.001 - 280 X 109 counts/display unit
AUDIO DIVIDE: 1, 10, 100, or 1000 events-per-click
RATEMETER ALERT/ALARM: Set at any value within the effective range of each detector
LINEARITY: Reading within ±10% of true value with detector connected
AUDIO: Built in unimorph speaker with ON/OFF switch (greater than 60 dB at 2 feet)
CALIBRATION CONTROLS: Accessible from front of instrument (protective cover provided)
RESET: Push-button to zero meter
POWER: 2 each “D” cell batteries (housed in sealed compartment that is externally accessible)
METER: 2.5” (6.4 cm) arc, 1 mA anlog type
CONSTRUCTION: Aluminum housing with beige powder coat paint
TEMPERATURE RANGE: -22 F (-30C) to 122 F (50C)
HUMIDITY: Less that 10% variance in reading from 5%-95% humidity

Manual

Nuclear Instrumentation

Dosimetry Shielding Sources Specials

Hepa Vacuums

Chemical Detection

Marinelli Beakers

Fume Hoods

Accessories

Emergency Response

Nuclear Medicine

Radiation Therapy Search Home

Direct Scientific    tel (310) 589 0601   fax (310) 919-2981,   Email

contact us: en español, auf Deutsch
Open 8:00 AM - 5:00 PM Pacific Standard Time