• Highly Sensitive Large Area Plastic Scintillation Detectors
  • Microprocessor Based Electronics
  • Audible and Visual Alarm Indicators
  • Dynamic Alarm Circuit for Optimal Sensitivity

Part Number - 48-3078


System Includes

1 ea. Microprocessor Based Electronics
2 ea. 480 in³ Plastic Detectors with 200'(61m) cables
1 ea. 5"(12.7cm) Diameter Red Alarm Strobe with 50'(15m) Cable
1 ea. 10 µCi(370 kBq) Cs-137 Check Source
1 ea. 40 Column Date/Time Printer

 


INDICATED USE: Radiation monitoring
SYSTEM OPERATION: Typically located at the scale/entrance area. The system will continuously monitor incoming materials for radiation. (Alarm can be set from 2 times background to just above background)
DETECTORS: 2 ea. 480 cubic inch (7866 cubic cm) shielded plastic scintillation detectors
AUDIO: Unimorph type speaker (greater than 68 dB at 2 feet(61 cm))
METER: 3.5" (6.4 cm) arc, 1 mA analog type
METER DIAL: 0 - 25 kcps
CHECKING (green LED):Indicates vehicle is passing through the system
SYSTEM OK (green LED): Indicates the system is functioning properly
CHANNEL 1: Pushbutton to check the count rate on channel 1
CHANNEL 2: Pushbutton to check the count rate on channel 2
ALARM: Indicated by a red LED's, red flashing lamp, and audible tone (Can be internally set from 4 - 34 deviations above background in increments of 2 )
Note: A deviation setting of 30 is approximately equivalent to 2 times background.
AUDIO ACKNOWLEDGE:
Push-button to silence the audio after an alarm has been indicated
ALARM RESET: Push-button to reset the alarm
FAIL 1 (yellow LED): Indicates when a signal is not received from detector 1
FAIL 2 (yellow LED): Indicates when a signal is not received from detector 2
RS-232: 9 pin connector to allow connection of a computer or printer for data logging.
CONTROLS: 5 pin connector allowing for connection of external alarm indicators
RELAYS: 3 pin connector allowing for connection of external alarm indicators
POWER: 95 - 135 VAC (178 - 240 VAC available), 50 - 60 Hz single phase (less than 100 mA)
ELECTRONICS CONSTRUCTION:Steel NEMA 12 enclosure
TEMPERATURE RANGE: -20 degrees F(-29 degrees C) to 140 degrees F(60 degrees C)
SIZE:(Electronics) 15" (38.1 cm)H X 12" (30.5 cm)W X 6.5" (16.5 cm)D
(Detectors)
72"(183 cm)H X 8"(20.3cm)Diameter
WEIGHT:(Electronics)
18 lbs (8.2 kg)
(Detectors) 65 lbs(30 kg) each
SHIPPING WEIGHT: 200 lbs (91 kg) shipped via UPS in 3 boxes

Nuclear Instrumentation

Dosimetry Shielding Sources Specials

Hepa Vacuums

Chemical Detection

Marinelli Beakers

Fume Hoods

Accessories

Emergency Response

Nuclear Medicine

Radiation Therapy Search Home

Direct Scientific    tel (310) 589 0601   fax (310) 919-2981,   Email

contact us: en español, auf Deutsch
Open 8:00 AM - 5:00 PM Pacific Standard Time