DSM-501 Digital Micro R Meter

WB Johnson DSM-501 Digital Micro R Survey meterThis microprocessor-controlled instrument represents the new gold standard of MicroR survey instruments. The auto-ranging DSM-501 is a digital instrument with a large, four digit backlit, LCD that displays a precise reading with no user intervention required. The micro R meter includes an internal 1 inch x 1 inch plastic scintillation detector. The detector is tissue equivalent and can measure gamma at the microR level as well as detect some betas. This newer design of plastic scintillation provides more accurate dose measurements than meters utilizing the traditional sodium iodide detectors. The DSM-501 is equipped with over-range alarms, regular alarms and diagnostics. An RS-232 data output is available on request.

The DSM-501 Survey MicroR Meter is is recommended for nuclear power plant, health physics, and medical applications, or whenever dose measurement at the micro R level is required. This micro R survey meter is ideal for NORM measurement. Other applications include oil refineries and scrap metal facilities. For the external probe version of this survey meter, try the DSM-500-MR. auf Deutsch

 

DSM-501 MicroRoentgen Survey Meter............... $1295 (order online)

DSM-501 Specifications

Input Sensitivity: 1 micro R
Display LCD: four digit x 0.75” Tall (19 mm) LCD W/LED Back light
LCD Refresh Rate: 0.8- 3.0 seconds in 0.2 second increments, adjustable
Display Back light: Push button on for 30 seconds, auto off
Dose Ranges: 0.0 μR/ hr to 25 μR/hr & 0.0 μSv/hr to 0.25 μSv/hr
CPM Ranges: 0-9999 cps, 0-9999 cpm & 0-999.9 Kcpm
Probe Linearization: Internal adjustment for calibration constant and dead time
Count Time: Ranges 10-2550 seconds in 10 second increments
Alarms: 5-95 % of range
Diagnostics: audible and visual alarms indicating low battery and over-range
Range Adjustment: Auto-ranging on all scales
Electrical Non-Linearity: < 5%
Response Time: Adjustable: Fast 10-250 seconds, Slow 10-250 seconds, adjustable Drift < 5%
Environmental: -20⁰F (-28⁰C) to 140⁰F (60⁰C), 5-95% RH IPX4 Housing
High Voltage: Adjustable 300-1500 VDC, Regulation ±1%
Battery: six AA Alkaline, Nominal 100 hours of operation
Circuitry: Digital Microprocessor Controlled
Dimensions: 5.5" (14cm) H X 4" (10cm) W X 7" (18cm) L
Weight: 2.5 lbs (1.1 kg) with Batteries
Construction: Heavy Duty Cast Aluminum & Stainless Steel
Detector: Internal tissue equivalent plastic scintillator, 1"x1"


Nuclear Instrumentation

Dosimetry Shielding Sources Specials

Hepa Vacuums

Chemical Detection

Marinelli Beakers

Fume Hoods

Accessories

Emergency Response

Nuclear Medicine

Radiation Therapy Search Home

Direct Scientific    tel (310) 589 0601   fax (310) 919-2981,   Email

contact us: en español, auf Deutsch