GSM-525 Four Range, Dual-Probe Microprocessor Survey Meter
![]()

The GSM-525 features calibration for two different probes measuring in both counts and dose. Other features include auto-ranging, integration, peak hold, and auto dose linearization of each probe. This survey meter is recommended when two different probes are needed for different applications. It saves the user from purchasing a second survey meter. This survey meter is ideal for emergency response teams.
Calibration: CPM and Dose (mR/hr or mSv/hr based on Cs137 Calibration)
Channel #1 Probe Compatibility: GP-200 End Window probe, HP-265 Pancake G-M Probe, GLE-1 Low Energy NaI probe, GP-1001 Energy compensated Cylindrical G-M probe, GSP-1 NaI Scintillation Probe 1"x1", GSP-2 NaI Scintillation Probe 2"x2", and ASP-2A Alpha Scintillation probe
Channel #2 Probe Compatibility: GLE-1 Low Energy NaI probe, GSP-1 NaI Scintillation Probe 1"x1", GSP-2 NaI Scintillation Probe 2"x2", ASP-2A Alpha Scintillation probe
Ranges #1 Probe: 0-.2, 0-2, 0-20, & 0-200 mR/hr or
0-500, 0-5000 & 0-50,000, & 0-500,000 cpm
Ranges #2 Probe: 0-500, 0-5000 &
0-50,000, & 0-500,000 cpm-Cannot be dose calibrated.
Diagnostics: Visuaul low battery, detector saturation and HV out-of-range
Adjustable high voltage: 300 - 1300 volts ±1%
Audio Output: On-Off Front Panel Switch, Water & solvent resistant
Power Supply: QTY six AA Alkaline batteries
Display: 3.5 inch Rugged water resistant panel meter, analog
Dimensions: 5-½" (14 cm) H X 4" (10 cm) W X 7" (18 cm)
Weight: 2-1/4 Pounds (1 kg)
Construction: Heavy Duty Cast Aluminum and Stainless Steel
Enivornmental: Stable from - 20° c to 60° c, IPX4, moisture resistant
|
Direct Scientific tel (888) 368 9118 or (310) 589 0601 fax (310) 919-2981, Email |
|
|